莘默供應(yīng)COMET AG MXR 100 30 射線管

數(shù)量(件) 價格
10 100500.00元/件
  • 最小起訂: 1件
  • 發(fā)貨地址: 上海 嘉定區(qū)
  • 發(fā)布日期:2021-05-12
  • 訪問量:433
咨詢電話:177-5769-1911
打電話時請告知是在機電之家網(wǎng)上看到獲取更多優(yōu)惠。謝謝!
5
  • 聯(lián)系人:許劍星
  • 手機:17757691911
  • 電話:021-60712995
  • 營業(yè)執(zhí)照:已審核 營業(yè)執(zhí)照
  • 經(jīng)營模式: 貿(mào)易公司-股份有限公司
  • 所在地區(qū):上海 嘉定區(qū)
  • 家家通積分:38分
詳細參數(shù)
品牌COMET型號MXR10030
類型X射線CT管產(chǎn)品等級一級品
執(zhí)行標準歐標產(chǎn)品認證UL
加工定制是否進口
燈絲電壓5.3V燈絲電流3.6安
焦點尺寸d,5.5mm輻射角30°
管電壓90kV功率1000W
重量2.1KG產(chǎn)地其他

產(chǎn)品詳情

MXR-100/30

 

 

 

 


 

 

 

 

 

Product Specifications

Product Debion

The MXR-100/30 is an unipolar water-cooled tube assembly without integrated radiation protection. It comprises a single focal spot, a tungsten anode and a directional beam. The tube is specifically designed for thickness gauging and sorting applications.


 

Nominal tube voltage kV

Continuous rating 1000W

Focal spot acc. EN 12543 d = 5.5 mm

Focal spot acc. ASTM E1165-12 N/A

Filament current, max. 3.6 A

Filament voltage, typical V

Inherent filtration 0.8 ± 0.1 mm Be

Target material W

Target angle 30°

Radiation coverage 40° x 40°

Leakage radiation, max. at loading factors in 1m distance 2.5 mSv/h (100 kV; 10 mA)

Weight 2.1 kg

Terminal type CA11

Power rating charts

Power rating at given filament current


 

Connection of the filament


 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Cooling medium Water

Cooling medium flow, min. 4 l/min

Cooling medium temperature at  inlet, max. 35°; optimal 20°-35°, no water condensation /

kein Kondenswasser

Pressure at cooling medium inlet, max. 6 bar

Post-cooling time after switchoff, min. 2 min


Outline drawing

 

 

 

66.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Die radiographischen Kenndaten sind dem Prüfschein des Strahlers zu entnehmen.

For radiographic characteristics of the tube refer to Final Test Report.


 

Masse ohne Toleranzangabe sind nur zur Inbation. Dimensions without tolerances are for inbation only.

General inbation

 


General

The control of the high voltage and the filament current as well as the design of the cooling system and the radiation protection are within the responsibility of the original equipment manufacturer (OEM). For detailed instructions refer to

our ?X-Ray Tube Manual“. Provisions in the generator must assure that the X-Ray tube will be protected against overcurrent, over- voltage and lack of cooling. Otherwise the tube and/or the radiation protection may be damaged and become a hazard.

Cooling

The customer is in charge that the cooling circuit is properly connected to the cooling system. Prior to operating the tube, the coolant must be turned on. Make sure that the coolant flow meets the required cooling conditions. When the tube is switched off, the coolant flow must continue for at least 2 minutes in order to protect the anode and the lead protection from overheating.

 

Radiation protection

When installing an X-ray tube assembly into a X-ray equipment and/or operating an X-ray equipment, the responsibility for radiation protection is with the user. Compliance with local regulatory requirements and limit valu- es must be assured. Do not modify the tube assembly itself!



溫馨提示

  • 還沒找到想要的產(chǎn)品嗎? 立即發(fā)布采購信息,讓供應(yīng)商主動與您聯(lián)系!

免責(zé)聲明:所展示的信息由會員自行提供,內(nèi)容的真實性、準確性和合法性由發(fā)布會員負責(zé),機電之家網(wǎng)對此不承擔(dān)任何責(zé)任。機電之家網(wǎng)不涉及用戶間因交易而產(chǎn)生的法律關(guān)系及法律糾紛,糾紛由您自行協(xié)商解決。
友情提醒:本網(wǎng)站僅作為用戶尋找交易對象,就貨物和服務(wù)的交易進行協(xié)商,以及獲取各類與貿(mào)易相關(guān)的服務(wù)信息的平臺。為避免產(chǎn)生購買風(fēng)險,建議您在購買相關(guān)產(chǎn)品前務(wù)必確認供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。過低的價格、夸張的描述、私人銀行賬戶等都有可能是虛假信息,請采購商謹慎對待,謹防欺詐,對于任何付款行為請您慎重抉擇!如您遇到欺詐等不誠信行為,請您立即與機電之家網(wǎng)聯(lián)系,如查證屬實,機電之家網(wǎng)會對該企業(yè)商鋪做注銷處理,但機電之家網(wǎng)不對您因此造成的損失承擔(dān)責(zé)任!
您也可以進入“消費者防騙指南”了解投訴及處理流程,我們將竭誠為您服務(wù),感謝您對機電之家網(wǎng)的關(guān)注與支持!

您是不是在找